1 – CLI Overview
Page 2 Airborne™ Product Family CLI Reference Guide 100-8005-101G
Quatech, Inc. Confidential
The CLI Server listens on the TCP port specified by the wl-telnet-port
parameter. The default is 23.
The CLI Server inactivity timer is configured via the wl-telnet-timeout
command.
The CLI Server uses the wl-telnet-timeout value to timeout and close TCP
connections that are inactive.
The CLI Server supports up to three (3) TCP sessions.
1.2.2 CLI Security
The CLI Server supports five (5) levels of security for each CLI Session. The security levels
provide a safeguard for the set of CLI commands that may be executed by users. CLI Sessions
that are authenticated at a particular security level may execute all CLI commands specified for
that security level and below.
The Module’s five (5) levels of security are:
Level 0 (L0) = connectionless
Level 1 (L1) = connection, not logged in (default)
Level 2 (L2) = data
Level 3 (L3) = config
Level 4 (L4) = OEM
Level 5 (L5) = MFG
Level 0 is the connectionless access level. Access over UDP will use this access level. The L0
level provides access to the name query services. It is not an authenticated level.
Level 1 is the default security level for CLI Sessions over TCP or the serial interface.
CLI Sessions must execute the CLI command auth in order to authenticate the CLI Sessions to
another security level. The CLI command definition tables in the following chapter include a
column labeled Ln that indicates the access level required to execute each command. The CLI
command logout returns the CLI Session back to security Level 1.
1.2.3 CLI Session Modes
The mode of the CLI Session governs the set of actions allowed in the CLI session. The
following are descriptions of each mode:
1.2.4 CLI Mode
CLI Mode is the command processing mode of the CLI Session. CLI Mode allows users and
OEM applications to simply execute Airborne™ WLN Module commands as described in the
section, “CLI Commands.”